Filter Presses — Darcy-Ruth & Timoshenko 16 bar

FILTRATION & DEWATERING • 800 TO 1500 MM

Calibrate feed pressure (up to 16 bar), plate dimensions (800–1500 mm), and target cake moisture (≤ 16% NOM-141).

LIVE VERIFIER: 16-BAR PLATE STRENGTH & FILTRATION CYCLE
NOM-141 Moisture OK (14% ≤ 16%) SMAT-FILT-SHIFTER-CHAIN
Structurally safe operation. Meets NOM-141 dry cake criteria.
Bending σ_max: 3.54 MPa
Plate Safety: FS 4.10
Cycle Capacity: 36 c/d · 285 t/d
NOM-141 Ruling: NOM-141 OK
Cycle Timing: Filtration 18.0 min + Turnaround 12 min = 30.0 min
Asymmetric ΔP / Fatigue: ΔP = 0.00 MPa | σ_adm,PP = 14.5 MPa
Plate & Cloth SKUs: Placa: SMAT-FILT-CLOTH-PLATE | Tela: SMAT-CL-PP750

Filter Press Engineering Specifications

Engineered to reach 12%–16% residual cake moisture with maximum closed-circuit water recovery.

Design ParameterSMAT Specification
Plate Dimensions800×800 mm, 1000×1000 mm, 1200×1200 mm, 1500×1500 mm
Feed / Clamping PressureSlurry up to 16 bar · Hydraulic closure up to 350 bar
Darcy-Ruth & NOM-141α = α₀ (ΔP)ˢ (s = 0.65) · SEMARNAT NOM-141 (≤ 16% moisture)
Plate ShiftingAutomated plate shifter carriage, chains & cylinder seals
PLANT METALLURGICAL SELECTION MATRIX

Selection Matrix (Placas de 800x800 mm a 1500x1500 mm)

Required Slurry VarsSlurry feed volume (t/h), initial solids percentage, and target cake residual moisture (< 15% for geotechnical dry stacking).
Chamber & Weave RuleRecessed chamber and membrane squeeze plates for secondary compression. 10 to 16 bar filtration pressure with heavy-duty structural sidebars.
Mitigated RiskPrevents wet unstable filter cakes unsuitable for dry stacking and excessive cycle discharge downtime.
CONTEXTUAL PRE-SELECTION • QUOTE BRIDGE

Select Plate Format & Dewatering Duty