UNIVERSAL STANDARD SPARE

D4029

High Chrome A05 Expeller Ring & Chamber for 6x4

Quote D4029 →
STATION-COUPLED PREVENTIVE REPLACEMENT WINDOW (3 MILESTONES)Session Pulp SG 1.45 • d50 280 µm
SHAFT SLEEVE (STAGE 1)Day 45
IMPELLER + THROAT (STAGE 2)Day 90
VOLUTE + LINER (STAGE 3)Day 180
Recommended reorder window:90 d windowRaw life: 100 d 1.00× (1.00×) Tray: v3
Criticality Mode:

Cast Cr27 A05 static expeller ring with internal vortex-breaking ribs and grease port, engineered to operate alongside the D4028 expeller and D075C21 shaft sleeve.

[1. MASS & NIOSH RIGGING]
24.5 kg
Hoist / Crane Mandatory (HOIST_REQUIRED • LI=2.21 ≥ 23 kg)
Wall thickness: 22 mm
[2. HYDRAULIC GEOMETRY]
∅D₂ = 290 mm
Max sphere passage: 20 mm
SMAT Code: SMAT-SEAL-4X3-EXR
[3. BOM ASSEMBLY STATION]
Station 02 (S2)
06. Anillo Expulsor D4029 (Estación 02 • Laberinto Seco)

Metallurgical Specifications & Dimensional Interchangeability

Universal Code: D4029 (SMAT-SEAL-4X3-EXR)
Compatible Frame & Pipe Series: Slurry pump Standard Frame (4X3)
Component Type: Static Centrifugal Seal Containment Ring
Metallurgy: High Chrome A05 (27% Cr, ASTM A532 Class III Type A)
Verified Hardness: ≥ 650 HB (Brinell) / 58-62 HRC
Critical Application: Static housing for D4028 expeller and stuffing box in 6x4 pumps
Assembly Guarantee: Flange flatness and stuffing box concentricity verified in Durango. (Linked Kits: #3)
Everyday Physical Scale (ISO/IEC 7810): Optimal reference axial clearance δ = 0.76 mm (exact thickness of 1 standard ISO 7810 bank card).

1:1 Dimensional Fit Assurance (ISO 2768-m)

Every D4029 unit is physically matched against standard frame dimensions before dispatch from our Durango Central Warehouse. We ensure 100% drop-in interchangeability with industry-standard frames. Should a standard replacement part deviate from confirmed drawings, priority replacement is coordinated under our Durango supply regime.

CONFIDENTIAL ENGINEERING NOTICE:

Fine-tolerance manufacturing prints and complete internal dimensional matrices are kept off public tables to safeguard intellectual property. Detailed mechanical drawings and compliance dossiers are shared privately with authorized mine plant engineering and procurement teams.