UNIVERSAL STANDARD SPARE

DAM005

Complete Cartridge Bearing Assembly 6x4

Quote DAM005 →
STATION-COUPLED PREVENTIVE REPLACEMENT WINDOW (3 MILESTONES)Session Pulp SG 1.45 • d50 280 µm
SHAFT SLEEVE (STAGE 1)Day 45
IMPELLER + THROAT (STAGE 2)Day 90
VOLUTE + LINER (STAGE 3)Day 180
Recommended reorder window:90 d windowRaw life: 100 d 1.00× (1.00×) Tray: v3
Criticality Mode:

Tapered roller bearing cartridge in back-to-back arrangement (ISO 281) sealed with grease-purged labyrinths to withstand severe V-belt radial loads.

[1. MASS & NIOSH RIGGING]
54 kg
Hoist / Crane Mandatory (HOIST_REQUIRED • LI=4.86 ≥ 23 kg)
Wall thickness: 28 mm
[2. HYDRAULIC GEOMETRY]
∅D₂ = 380 mm
Max sphere passage: 45 mm
SMAT Code: SMAT-PUMP-6X4-BRG
[3. BOM ASSEMBLY STATION]
Station 01 (S1)
01. Cartucho de Rodamientos DAM005 (Estación 01 • Ajuste Axial)

Metallurgical Specifications & Dimensional Interchangeability

Universal Code: DAM005 (SMAT-PUMP-6X4-BRG)
Compatible Frame & Pipe Series: Slurry pump Standard Frame (6X4)
Component Type: Mechanical Shaft & Bearing Housing Sub-assembly ISO 281
Metallurgy: Acero Aleado SAE 4140 + Hierro Dúctil GGG40 + Sellos de Laberinto Purgante
Verified Hardness: Eje bonificado 280-320 HB / Pistas 60-62 HRC
Critical Application: Drive end of 6x4 slurry pumps with micrometer axial clearance adjustment
Assembly Guarantee: Drop-in interchangeability in standard base frame verified prior to shipping from Durango. (Linked Kits: #4)
Everyday Physical Scale (ISO/IEC 7810): Optimal reference axial clearance δ = 0.76 mm (exact thickness of 1 standard ISO 7810 bank card).

1:1 Dimensional Fit Assurance (ISO 2768-m)

Every DAM005 unit is physically matched against standard frame dimensions before dispatch from our Durango Central Warehouse. We ensure 100% drop-in interchangeability with industry-standard frames. Should a standard replacement part deviate from confirmed drawings, priority replacement is coordinated under our Durango supply regime.

CONFIDENTIAL ENGINEERING NOTICE:

Fine-tolerance manufacturing prints and complete internal dimensional matrices are kept off public tables to safeguard intellectual property. Detailed mechanical drawings and compliance dossiers are shared privately with authorized mine plant engineering and procurement teams.