UNIVERSAL STANDARD SPARE

E4132

Frame Plate Liner Insert (FPL) in R55 Elastomer for 6x4

Quote E4132 →
STATION-COUPLED PREVENTIVE REPLACEMENT WINDOW (3 MILESTONES)Session Pulp SG 1.45 • d50 280 µm
SHAFT SLEEVE (STAGE 1)Day 45
IMPELLER + THROAT (STAGE 2)Day 90
VOLUTE + LINER (STAGE 3)Day 180
Recommended reorder window:90 d windowRaw life: 100 d 1.00× (1.00×) Tray: v3
Criticality Mode:

Rear frame plate liner insert in R55 natural anti-abrasive rubber with vulcanized steel backing to absorb fine-particle elastic impact without flat gaskets.

[1. MASS & NIOSH RIGGING]
9.8 kg
1-Operator Manual Safe (MANUAL_SAFE • LI=0.88)
Wall thickness: 26 mm
[2. HYDRAULIC GEOMETRY]
∅D₂ = 380 mm
Max sphere passage: 12 mm
SMAT Code: SMAT-PUMP-6X4-FPL
[3. BOM ASSEMBLY STATION]
Station 03 (S3)
08. Forro de Plato Posterior E4132 (Estación 03 • Hule R55 / PU)

Metallurgical Specifications & Dimensional Interchangeability

Universal Code: E4132 (SMAT-PUMP-6X4-FPL)
Compatible Frame & Pipe Series: Slurry pump Standard Frame (6X4)
Component Type: Rear Wet-End Chamber Liner Insert
Metallurgy: Elastómero de Caucho Natural Vulcanizado R55 (Shore A 55 ± 5)
Verified Hardness: 55 ± 5 Shore A (Resiliencia de Rebote ≥ 70%)
Critical Application: Secondary classification, flotation, and fine slurry pumping (d80 < 250 microns)
Assembly Guarantee: Vulcanized studs and perimeter sealing lip verified at Durango Central Warehouse. (Linked Kits: #2)
Everyday Physical Scale (ISO/IEC 7810): Optimal reference axial clearance δ = 0.76 mm (exact thickness of 1 standard ISO 7810 bank card).

1:1 Dimensional Fit Assurance (ISO 2768-m)

Every E4132 unit is physically matched against standard frame dimensions before dispatch from our Durango Central Warehouse. We ensure 100% drop-in interchangeability with industry-standard frames. Should a standard replacement part deviate from confirmed drawings, priority replacement is coordinated under our Durango supply regime.

CONFIDENTIAL ENGINEERING NOTICE:

Fine-tolerance manufacturing prints and complete internal dimensional matrices are kept off public tables to safeguard intellectual property. Detailed mechanical drawings and compliance dossiers are shared privately with authorized mine plant engineering and procurement teams.